File:Accumulation-and-transport-of-microbial-size-particles-in-a-pressure-protected-model-burn-unit-CFD-1471-2334-11-58-S1.ogv
Accumulation-and-transport-of-microbial-size-particles-in-a-pressure-protected-model-burn-unit-CFD-1471-2334-11-58-S1.ogv (Ogg multiplexed audio/video file, Theora/Vorbis, length 26 s, 640 × 480 pixels, 332 kbps overall, file size: 1.03 MB)
Captions
Summary edit
DescriptionAccumulation-and-transport-of-microbial-size-particles-in-a-pressure-protected-model-burn-unit-CFD-1471-2334-11-58-S1.ogv |
English: Movie1 - patient room. Dynamic representation of air-flows in the patient room with source contamination arising from the patient table. Colors represent the fraction of source contamination, with highest concentrations in red and lowest in blue. A contamination accumulation is entrained by heat convection currents into the upper part of the room between the air diffusion panels and room walls. (mpeg2 movie sequence) |
||
Date | |||
Source | Beauchêne C, Laudinet N, Choukri F, Rousset J, Benhamadouche S, Larbre J, Chaouat M, Benbunan M, Mimoun M, Lajonchère J, Bergeron V, Derouin F (2011). "Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence". BMC Infectious Diseases. DOI:10.1186/1471-2334-11-58. PMID 21371304. PMC: 3056797. | ||
Author | Beauchêne C, Laudinet N, Choukri F, Rousset J, Benhamadouche S, Larbre J, Chaouat M, Benbunan M, Mimoun M, Lajonchère J, Bergeron V, Derouin F | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 16:35, 6 December 2012 | 26 s, 640 × 480 (1.03 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Additional file 1 |
---|---|
Author | |
Usage terms | http://creativecommons.org/licenses/by/2.0/ |
Image title | Movie1 - patient room. Dynamic representation of air-flows in the patient room with source contamination arising from the patient table. Colors represent the fraction of source contamination, with highest concentrations in red and lowest in blue. A contamination accumulation is entrained by heat convection currents into the upper part of the room between the air diffusion panels and room walls. (mpeg2 movie sequence) |
Software used | |
Date and time of digitizing | 2011 |