English: Active emergency core cooling system (ECCS):

A - area inside containment structure
B - area outside containment structure
1 - ECCS water storage
2 - ECCS low-pressure pump
3 - non-return valve
4 - drain-well
5 - heat exchanger
6 - ECCS water storage
7 - ECCS high-pressure pump
8 - containment structure wall
9 - water output to reactor

1 and 2 create high pressure coolant injection system (HPCI). 6 and 7 create low pressure coolant injection system (LPCI).
Polski: Aktywny układ awaryjnego chłodzenia reaktora (AUACR):

A - obszar wewnątrz obudowy bezpieczeństwa
B - obszar poza obudową bezpieczeństwa
1 - zbiornik wody UACR
2 - pompa niskociśnieniowa UACR
3 - zawór zwrotny
4 - studzienka ściekowa
5 - wymiennik ciepła
6 - zbiornik wody UACR
7 - pompa wysokociśnieniowa UACR
8 - ściana obudowy bezpieczeństwa
9 - ujście wody do reaktora

1 i 2 tworzą układ wysokociśnieniowego wrzutu wody. 6 i 7 tworzą układ niskociśnieniowego wrzutu wody.
Date
Source Own work
Author NH2501

Licensing edit

I, the copyright holder of this work, hereby publish it under the following licenses:
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 4.0 International, 3.0 Unported, 2.5 Generic, 2.0 Generic and 1.0 Generic license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
You may select the license of your choice.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current13:02, 24 April 2011Thumbnail for version as of 13:02, 24 April 2011790 × 275 (39 KB)NH2501 (talk | contribs){{Information |Description ={{en|1=Active emergency core cooling system (ECCS):<br/> A - area inside containment structure<br/> B - area outside containment structure<br/> 1 - ECCS water storage<br/> 2 - ECCS low-pressure pump<br/> 3 - non-return valve

There are no pages that use this file.

File usage on other wikis

The following other wikis use this file: