File:Heat-loss calorimeter.gif

Original file(2,160 × 2,578 pixels, file size: 951 KB, MIME type: image/gif)

Captions

Captions

Add a one-line explanation of what this file represents


--Shkedi 18:47, 28 February 2008 (UTC)

Summary edit

Description Cross-section view of a heat-loss calorimeter. The heat developed inside the cell is collected by the inner copper cup. Then, it flows through the silicone-rubber which serves as a thermal resistor and the outer copper cup, to the flowing water surrounding the outer copper cup.
Date
Source Own work
Author Zvi Shkedi

Licensing edit

w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
Attribution: Designed by Z. Shkedi et al.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.

Original upload log edit

date/time username resolution size edit summary
21:01, 28 February 2008 User:Shkedi <a href="http://upload.wikimedia.org/wikipedia/commons/9/96/Thermal_gradient_calorimeter.gif"><img alt="Thumbnail for version as of 21:01, 28 February 2008" src="http://upload.wikimedia.org/wikipedia/commons/9/96/Thermal_gradient_calorimeter.gif" width="100" height="119" border="0" /></a>2,160×2,578 951 KB
05:09, 28 February 2008 User:Shkedi <a href="http://upload.wikimedia.org/wikipedia/commons/archive/9/96/20080228210107%21Thermal_gradient_calorimeter.gif"><img alt="Thumbnail for version as of 05:09, 28 February 2008" src="http://upload.wikimedia.org/wikipedia/commons/archive/9/96/20080228210107%21Thermal_gradient_calorimeter.gif" width="99" height="120" border="0" /></a>823×1,000 44 KB {{Information |Description=A thermal gradient calorimeter. The thermal gradient is formed between the inner-copper-cup and the outer-copper-cup, across the silicone rubber which serves as a thermal resistor. The heat developed inside the cell flows throug

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current20:49, 21 November 2008Thumbnail for version as of 20:49, 21 November 20082,160 × 2,578 (951 KB)BetacommandBot (talk | contribs)move approved by: User:Deadstar This image was moved from Image:Thermal gradient calorimeter.gif --Shkedi 18:47, 28 February 2008 (UTC) == Summary == {{Information |Description=Cross-section view of a heat-loss calorimeter. The

There are no pages that use this file.