File:Increased-Vulnerability-of-Human-Ventricle-to-Re-entrant-Excitation-in-hERG-linked-Variant-1-Short-pcbi.1002313.s003.ogv
Increased-Vulnerability-of-Human-Ventricle-to-Re-entrant-Excitation-in-hERG-linked-Variant-1-Short-pcbi.1002313.s003.ogv (Ogg Theora video file, length 6.9 s, 529 × 333 pixels, 474 kbps, file size: 398 KB)
Captions
Summary edit
DescriptionIncreased-Vulnerability-of-Human-Ventricle-to-Re-entrant-Excitation-in-hERG-linked-Variant-1-Short-pcbi.1002313.s003.ogv |
English: WT reentry in realistic 2D geometry. Re-entrant spiral waves generated by the application of a premature S2 stimulus into the refractory and partially recovered region of an excitation wave after a delay of 400 ms rom the initial wave stimulus under the wild type (control) condition. The induced spiral waves transition from transmural re-entry with tip rotating within the ventricle wall to anatomical re-entry with tip rotating around the ventricle boundary and self-terminate within 2000 ms. |
||
Date | |||
Source | Video S3 from Adeniran I, McPate M, Witchel H, Hancox J, Zhang H (2011). "Increased Vulnerability of Human Ventricle to Re-entrant Excitation in hERG-linked Variant 1 Short QT Syndrome". PLOS Computational Biology. DOI:10.1371/journal.pcbi.1002313. PMID 22194679. PMC: 3240585. | ||
Author | Adeniran I, McPate M, Witchel H, Hancox J, Zhang H | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 17:00, 30 October 2012 | 6.9 s, 529 × 333 (398 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Adeniran I, McPate M, Witchel H, Hancox J, Zhang H |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | WT reentry in realistic 2D geometry. Re-entrant spiral waves generated by the application of a premature S2 stimulus into the refractory and partially recovered region of an excitation wave after a delay of 400 ms rom the initial wave stimulus under the wild type (control) condition. The induced spiral waves transition from transmural re-entry with tip rotating within the ventricle wall to anatomical re-entry with tip rotating around the ventricle boundary and self-terminate within 2000 ms. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2011-12 |