DescriptionPlatino Report - Preventer Load by Angle.gif |
English: Boom en:preventer load factor, by angle of incident to the boom. When the preventer is rigged just forward of the boom instead of all the way to the bow, the line load multiplies significantly.
Deutsch: Multiplikator für die Belastung des de:Bullenstanders, in Abhängigkeit vom Winkel zwischen diesem und dem Baum. Bei sehr kleinen Winkeln steigt die Belastung nichtlinear. Die vertikale Komponente ist nicht berücksichtigt. |
Date | |
Source | Own work, after Report on the Platino accident (in en). Maritime New Zealand (2016). Retrieved on 2018-11-10. |
Author | User:PaterMcFly, Maritime New Zealand |
From Report on the Platino accident (in en). Maritime New Zealand (2016). Retrieved on 2018-11-10. Page 27
Data points:
Angle | Factor |
---|---|
90 | 1 |
85 | 1 |
80 | 1.02 |
75 | 1.04 |
70 | 1.07 |
65 | 1.1 |
60 | 1.16 |
55 | 1.22 |
50 | 1.31 |
45 | 1.41 |
40 | 1.56 |
35 | 1.74 |
30 | 2 |
25 | 2.37 |
20 | 2.92 |
15 | 3.86 |
10 | 5.76 |
5 | 11.5 |
Licensing edit
I, the copyright holder of this work, hereby publish it under the following license:
This file is made available under the Creative Commons CC0 1.0 Universal Public Domain Dedication. | |
The person who associated a work with this deed has dedicated the work to the public domain by waiving all of their rights to the work worldwide under copyright law, including all related and neighboring rights, to the extent allowed by law. You can copy, modify, distribute and perform the work, even for commercial purposes, all without asking permission.
http://creativecommons.org/publicdomain/zero/1.0/deed.enCC0Creative Commons Zero, Public Domain Dedicationfalsefalse |
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 13:45, 9 December 2018 | 537 × 353 (10 KB) | PaterMcFly (talk | contribs) | {{Information |description ={{en|1=Boom en:preventer load factor, by angle of incident to the boom. When the preventer is rigged just forward of the boom instead of all the way to the bow, the line load multiplies significantly.}} {{de|1=Multiplikator für die Belastung des de:Bullenstanders, in Abhängigkeit vom Winkel zwischen diesem und dem Baum. Bei sehr kleinen Winkeln steigt die Belastung nichtlinear. Die vertikale Komponente ist nicht berücksichtigt. }} |date =2016-0... |
You cannot overwrite this file.
File usage on Commons
The following 2 pages use this file:
File usage on other wikis
The following other wikis use this file:
- Usage on de.wikipedia.org