File:Structure-Guided-Mutations-in-the-Terminal-Organelle-Protein-MG491-Cause-Major-Motility-and-ppat.1005533.s013.ogv
No higher resolution available.
Structure-Guided-Mutations-in-the-Terminal-Organelle-Protein-MG491-Cause-Major-Motility-and-ppat.1005533.s013.ogv (Ogg Theora video file, length 31 s, 600 × 600 pixels, 227 kbps, file size: 846 KB)
File information
Structured data
Captions
Summary edit
DescriptionStructure-Guided-Mutations-in-the-Terminal-Organelle-Protein-MG491-Cause-Major-Motility-and-ppat.1005533.s013.ogv |
English: Time-lapse microcinematography of M . genitalium mg491-F157A-F158A cells. Red arrows point to motile minute cells showing no Hoechst fluorescence in S7 Fig. Blue arrow points to a non-motile minute cell showing no Hoechst fluorescence in S7 Fig. Bar is 5 μm. |
||
Date | |||
Source | S5 Movie from Martinelli L, García-Morales L, Querol E, Piñol J, Fita I, Calisto B (2016). "Structure-Guided Mutations in the Terminal Organelle Protein MG491 Cause Major Motility and Morphologic Alterations on Mycoplasma genitalium". PLOS Pathogens. DOI:10.1371/journal.ppat.1005533. PMID 27082435. PMC: 4833410. | ||
Author | Martinelli L, García-Morales L, Querol E, Piñol J, Fita I, Calisto B | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 16:54, 12 October 2016 | 31 s, 600 × 600 (846 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
The following page uses this file:
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Time-lapse microcinematography of M . genitalium mg491-F157A-F158A cells. |
---|---|
Author | Martinelli L, García-Morales L, Querol E, Piñol J, Fita I, Calisto B |
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Red arrows point to motile minute cells showing no Hoechst fluorescence in S7 Fig. Blue arrow points to a non-motile minute cell showing no Hoechst fluorescence in S7 Fig. Bar is 5 μm. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2016-04-15 |