File:ABB E201 versus ABB SH201.JPG

Original file(7,300 × 5,470 pixels, file size: 7.33 MB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents
Description
English: Difference between circuit breaker and load switch.
  • Problem: many people use circuit breaker as main disconnector, which creates some danger situation. This image shows, that circuit breaker with broken actuator is able to make some false illusion, that danger voltage is missing.
Русский: Отличие автомата защиты от рубильника.
  • Проблема: очень многие псевдоэлектрики на строительных форумах и за их пределами используют автомат защиты в качестве вводного разъединителя нагрузки в электрощитах, чем создают опасную ситуацию. Эта иллюстрация показывает, что автомат защиты с амортизированным механизмом привода будет создавать роковую иллюзию снятого напряжения.
Date
Source Own work
Author Dmitry G
Permission
(Reusing this file)
I, the copyright holder of this work, hereby publish it under the following licenses:
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.
You may select the license of your choice.
Annotations
InfoField
This image is annotated: View the annotations at Commons

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current15:11, 27 September 2012Thumbnail for version as of 15:11, 27 September 20127,300 × 5,470 (7.33 MB)Dmitry G (talk | contribs){{Information |Description={{en|1=Difference between circuit breaker and load switch. *Problem: many people use circuit breaker as main disconnector, which creates some danger situation. This image shows, that circuit breaker with broken actuator is a...

There are no pages that use this file.

Metadata