File:Implantation of recording ECoG probe into STS and ITG of Macaque.jpg
Size of this preview: 736 × 599 pixels. Other resolutions: 295 × 240 pixels | 590 × 480 pixels | 943 × 768 pixels | 1,258 × 1,024 pixels | 1,890 × 1,539 pixels.
Original file (1,890 × 1,539 pixels, file size: 2 MB, MIME type: image/jpeg)
File information
Structured data
Captions
Summary edit
DescriptionImplantation of recording ECoG probe into STS and ITG of Macaque.jpg |
English: Implantation of recording ECoG probe into STS and ITG. (A) Flexible electrode array to be implanted into STS. Individual electrode contacts are shown in the inset (dotted circles). (B) Low-magnification view of the left temporal lobe before probe implantation. STS was dissected from surface to bottom; LS, lateral sulcus. (C) High-magnification view of probe branches fitted to STS and ITG. (D) Low-magnification view of the left temporal lobe following implantation of electrode array. White arrowheads indicate probe branches inserted into STS. Black arrowheads denote branches on the surface of the STG. Scale bars indicate 5 mm. |
Date | Published online: 25 May 2011. |
Source | Matsuo T, Kawasaki K, Osada T, Sawahata H, Suzuki T, Shibata M, Miyakawa N, Nakahara K, Iijima A, Sato N, Kawai K, Saito N and Hasegawa I (2011) Intrasulcal electrocorticography in macaque monkeys with minimally invasive neurosurgical protocols. Front. Syst. Neurosci. 5:34. doi: 10.3389/fnsys.2011.00034 http://journal.frontiersin.org/article/10.3389/fnsys.2011.00034/full |
Author | Matsuo T, Kawasaki K, Osada T, Sawahata H, Suzuki T, Shibata M, Miyakawa N, Nakahara K, Iijima A, Sato N, Kawai K, Saito N and Hasegawa I |
Licensing edit
This file is licensed under the Creative Commons Attribution 4.0 International license.
- You are free:
- to share – to copy, distribute and transmit the work
- to remix – to adapt the work
- Under the following conditions:
- attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 04:12, 14 November 2015 | 1,890 × 1,539 (2 MB) | Was a bee (talk | contribs) | {{Information |Description={{en|1=Implantation of recording ECoG probe into STS and ITG. (A) Flexible electrode array to be implanted into STS. Individual electrode contacts are shown in the inset (dotted circles). (B) Low-magnification view of the lef... |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Width | 3,780 px |
---|---|
Height | 3,077 px |
Bits per component |
|
Compression scheme | LZW |
Pixel composition | RGB |
Orientation | Normal |
Number of components | 3 |
Horizontal resolution | 300 dpi |
Vertical resolution | 300 dpi |
Data arrangement | chunky format |
Software used | Adobe Photoshop CS5 Windows |
File change date and time | 11:02, 27 May 2011 |
Exif version | 2.21 |
Color space | Uncalibrated |
Date and time of digitizing | 19:45, 17 March 2011 |
Date metadata was last modified | 16:32, 27 May 2011 |
Unique ID of original document | uuid:5901c796-7212-4ada-9bb4-d505870e1146 |
IIM version | 42,615 |