File:Ulc exterior test frame storage.jpg

Original file(4,000 × 3,000 pixels, file size: 2.16 MB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents

Summary edit

Description
English: ULC exterior fire test frame storage. The horizontal frame is 5' x 10', used to hold horizontal test samples for the 4x9. The blue frames are for 5'x5' firestop wall openings in the wall panel test furnace. This narrows down the normal 10'x10' test sample size for a lower cost. The full scale panel furnace cannot be used for firestop tests because there is a column in the way of the 3' of penetrant sticking out of the unexposed side of the test sample per ULC-S115 or ASTM E814 or UL 1479. These penetrants would bump into the column on the way from the burn to the hose stream area by the overhead door. Dismounting the test sample from the rail, hooking it up to the furnace and then carrying it to the overhead door for the hose stream test takes too long and would violate the standards. By using the smaller 5'x5' frames, the sample sits inside the normal test frame and is rolled back and forth and around on casters. This procedure does not take into account the deflection experienced through the heating of metal studs on 10' tall framed walls, as in a normal 100ft² sample.
Date
Source Own work
Author Achim Hering

Licensing edit

I, the copyright holder of this work, hereby publish it under the following licenses:
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.
w:en:Creative Commons
attribution
This file is licensed under the Creative Commons Attribution 3.0 Unported license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
You may select the license of your choice.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current22:00, 21 June 2010Thumbnail for version as of 22:00, 21 June 20104,000 × 3,000 (2.16 MB)Achim Hering (talk | contribs){{Information |Description={{en|1=ULC exterior fire test frame storage. The horizontal frame is 5' x 10', used to hold horizontal test samples for the 4x9. The blue frames are for 5'x5' firestop wall openings in the wall panel test furnace. This narrows d

There are no pages that use this file.

Metadata