Description
English: Disorder in Soviet fuse box.
  • Those time fuse boxes were constructed to fit 6 or 9 or 12 circuit breakers, adding new circuits wasn't provided (cause powerful appliences were missing those time), to add new circuits you should install subpanel with enough place and move circuit breakers from main panel into subpanel. After reconstruction, this main panel should contain only main breaker and electricity meter; group breakers should be located in subpanel. Second quite serious mistake is using old Soviet and new European circuit breakers the same time - if you add new circuit and install circuit breaker, you should replace all circuit breakers with the same construction. And of course don't forget to measure loop impendance before choosing circuit breaker to avoid fire in future ;)
Русский: Неправильно установленные щитовые компоненты в щитовом шкафу.
  • При добавлении новых цепей, в случае нехватки места для аппаратов защиты в этажном щите, устанавливается квартирный щит (с достаточным количеством места для размещения необходимых щитовых аппаратов), куда и перемещаются необходимые аппараты защиты; таким образом в этажном щите остаётся только счётчик электроэнергии и главный предохранитель, групповые же предохранители переносятся в квартирный щит. Второй ошибкой является использование защитных аппаратов разных времён разной конструкции - в случае перестройки электроснабжения (в данном конкретном случае добавления новых цепей) электроустановочные компоненты должны быть изготовлены под текущие стандарты, т.е. не допускается переплетение стандартов различных времён; в данном случае все автоматы защиты должны иметь одинаковую конструкцию и быть изготовленными во временных рамках действия текущих стандартов. В качестве пожарной безопасности, перед выбором предохранителя на добавляемую линию следует закоротить провода в дальней точки линии и измерить сопротивление при коротком замыкании, вычислив тем самым ток короткого замыкания в конце линии во избежании пожара.
Date
Source [1]
Author Бабайсан
Permission
(Reusing this file)
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current14:24, 19 April 2011Thumbnail for version as of 14:24, 19 April 2011700 × 525 (393 KB)Dmitry G (talk | contribs){{Information |Description ={{en|1=Disorder in Soviet fuse box}} {{ru|1=Неправильно установленные щитовые компоненты в щитовом шкафу}} |Source =[http://www.electrik.org/forum/index.php?s=&sh

There are no pages that use this file.

Metadata