File:132 (CardioNetworks ECGpedia).jpg
Original file (2,987 × 1,440 pixels, file size: 4.9 MB, MIME type: image/jpeg)
Captions
Summary edit
Description132 (CardioNetworks ECGpedia).jpg |
This is an electrocardiogram recorded from a patient in his 80's after implantation of a pacemaker. This recording was made as part of a routine pacemakers follow-up The pacing system was working well . This is an interesting electrocardiogram which illustrates an important point regarding pacemaker lead implantation. It is clear that this patient's pacemaker is sensing his P waves and following with pacing of his ventricle. What is curious about this recording, is the right bundle branch block configuration of the QRS and the extreme rightward axis seen in lead one. It is for this reason, a routine electrocardiogram should be done after every pacemaker implantation that involves implanting a ventricular lead. In actual fact this patient's ventricular lead was pacing the left ventricle. This lead was probably in a branch of the coronary vein . The path of the lead can be traced by the CT video which was taken after this electrocardiogram was recorded. The patient had a pacemaker system that was working well, in spite of the fact that the pacemaker was pacing the left ventricle. In fact, new pacing techniques are pacing the left ventricle as well as the right ventricle to maintain cardiac synchronization. In this case though , the ventricular lead was removed, without complication, because of an associated infection of the pacemaker pocket. A new pacemaker was implanted from the right side with the new lead placed in the right of ventricle. This resulted in a markedly different electrocardiogram. |
|||
Date | ||||
Source | EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill | |||
Author | Michael Rosengarten BEng, MD.McGill | |||
Permission (Reusing this file) |
|
|||
CardioNetworks Source InfoField | 132.jpg |
ECGpedia Original upload log edit
Date/Time | Dimensions | User | Comment |
---|---|---|---|
11:09, 21 February 2012 | 3,004 × 1,599 (4.45 MB) | DarrelC (Talk • Contrib) |
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 21:59, 8 December 2013 | 2,987 × 1,440 (4.9 MB) | Cropbot (talk | contribs) | upload cropped version, operated by User:Andy king50. Summary: cropped caption/Watermark | |
19:41, 31 January 2013 | 3,004 × 1,599 (4.25 MB) | Smallbot (talk | contribs) | Commons:Batch uploading/ECGPedia: (Commons:Bots/Requests/Smallbot_8) Uploading ECGpediaCommons:Batch_uploading/AELG: Uploading photos |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
File usage on other wikis
The following other wikis use this file:
- Usage on en.wikiversity.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Camera manufacturer | HP |
---|---|
Camera model | HP Scanjet G3110 |
Date and time of data generation | 23:31, 2 May 2009 |
Width | 3,000 px |
Height | 1,599 px |
Bits per component |
|
Pixel composition | RGB |
Orientation | Normal |
Number of components | 3 |
Horizontal resolution | 72 dpi |
Vertical resolution | 72 dpi |
Software used | Adobe Photoshop CS5 Windows |
File change date and time | 06:36, 21 February 2012 |
Y and C positioning | Co-sited |
Pair of black and white reference values |
|
Exif version | 2.2 |
Meaning of each component |
|
Supported Flashpix version | 1 |
Color space | sRGB |
Saturation | Low saturation |
Sharpness | Soft |