File:A-Reaction-Diffusion-Model-of-ROS-Induced-ROS-Release-in-a-Mitochondrial-Network-pcbi.1000657.s006.ogv
A-Reaction-Diffusion-Model-of-ROS-Induced-ROS-Release-in-a-Mitochondrial-Network-pcbi.1000657.s006.ogv (Ogg Theora video file, length 1 min 38 s, 472 × 136 pixels, 1.13 Mbps, file size: 13.17 MB)
Captions
Summary
editDescriptionA-Reaction-Diffusion-Model-of-ROS-Induced-ROS-Release-in-a-Mitochondrial-Network-pcbi.1000657.s006.ogv |
English: Image sequence of a pair of TMRM-loaded canine ventricular myocytes (cell-cell junction indicated by the white arrow in left panel) which displayed 22 consecutive oscillations that originated at the end of the righthand cell. Images within each panel were acquired at a 1 second frame rate. Entrainment was indicated by an increase in the area of the oscillating cluster after a number of cycles until the whole cell (up to the border of the neighboring cell) was included. |
||
Date | |||
Source | Video S3 from Zhou L, Aon M, Almas T, Cortassa S, Winslow R, O'Rourke B (2010). "A Reaction-Diffusion Model of ROS-Induced ROS Release in a Mitochondrial Network". PLOS Computational Biology. DOI:10.1371/journal.pcbi.1000657. PMID 20126535. PMC: 2813265. | ||
Author | Zhou L, Aon M, Almas T, Cortassa S, Winslow R, O'Rourke B | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 13:39, 14 November 2012 | 1 min 38 s, 472 × 136 (13.17 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusFile usage on other wikis
The following other wikis use this file:
- Usage on es.wikipedia.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Zhou L, Aon M, Almas T, Cortassa S, Winslow R, O'Rourke B |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | Image sequence of a pair of TMRM-loaded canine ventricular myocytes (cell-cell junction indicated by the white arrow in left panel) which displayed 22 consecutive oscillations that originated at the end of the righthand cell. Images within each panel were acquired at a 1 second frame rate. Entrainment was indicated by an increase in the area of the oscillating cluster after a number of cycles until the whole cell (up to the border of the neighboring cell) was included. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2010-01 |