File:Data-of-the-molecular-dynamics-simulations-of-mutations-in-the-human-connexin46-docking-interface-mmc4.ogv
Size of this JPG preview of this OGG file: 800 × 429 pixels. Other resolutions: 320 × 172 pixels | 850 × 456 pixels.
Original file (Ogg multiplexed audio/video file, Theora/Vorbis, length 1 min 1 s, 850 × 456 pixels, 599 kbps overall, file size: 4.36 MB)
File information
Structured data
Captions
Captions
Add a one-line explanation of what this file represents
Summary
editDescriptionData-of-the-molecular-dynamics-simulations-of-mutations-in-the-human-connexin46-docking-interface-mmc4.ogv |
English: Movie S3 Supplementary video 3. Movie of the MD trajectory showing a close-up view of the binding interface between two hCx46N188Q connexins of opposing connexons. The complex dissociated within the first 10 ns of simulation. |
||
Date | |||
Source | Video file from Schadzek P, Schlingmann B, Schaarschmidt F, Lindner J, Koval M, Heisterkamp A, Ngezahayo A, Preller M (2016). "Data of the molecular dynamics simulations of mutations in the human connexin46 docking interface". Data in Brief. DOI:10.1016/j.dib.2016.01.067. PMID 26958636. PMC: 4764773. | ||
Author | Schadzek P, Schlingmann B, Schaarschmidt F, Lindner J, Koval M, Heisterkamp A, Ngezahayo A, Preller M | ||
Permission (Reusing this file) |
![]() ![]() This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 06:52, 29 October 2016 | 1 min 1 s, 850 × 456 (4.36 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Movie S3 |
---|---|
Author | Schadzek P, Schlingmann B, Schaarschmidt F, Lindner J, Koval M, Heisterkamp A, Ngezahayo A, Preller M |
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Supplementary video 3. Movie of the MD trajectory showing a close-up view of the binding interface between two hCx46N188Q connexins of opposing connexons. The complex dissociated within the first 10 ns of simulation. |
Software used | |
Date and time of digitizing | 2016-02-13 |