File:Drywall firestop problem1.jpg
![File:Drywall firestop problem1.jpg](https://upload.wikimedia.org/wikipedia/commons/thumb/6/66/Drywall_firestop_problem1.jpg/406px-Drywall_firestop_problem1.jpg?20070527225653)
Size of this preview: 406 × 599 pixels. Other resolutions: 162 × 240 pixels | 325 × 480 pixels | 520 × 768 pixels | 694 × 1,024 pixels | 2,336 × 3,448 pixels.
Original file (2,336 × 3,448 pixels, file size: 621 KB, MIME type: image/jpeg)
File information
Structured data
Captions
Captions
Add a one-line explanation of what this file represents
Summary
editDescriptionDrywall firestop problem1.jpg | This is typical passive fire protection problem. This wall is supposed to have a fire-resistance rating. It does not, because the firestop is inoperable. The plumber followed his instructions, to the letter, by providing a perfectly useless Section 15050 Schedule 40 sleeve, for one of the penetrants, a steel pipe. His insulator shoved in some packing and smeared in some firestop silicone. Two other penetrants did not get sleeved because the sleeve did not fit, so they were just left. The drywaller tried to "mud up" to the resulting mess and there is no way the result will stop any smoke or fire. The problem started with having each sub-trade do its own firestopping and not insisting on a separate firestop sub-trade, working for the general contractor, with clear penetration sizing and shaping guidelines. As it is, this mess destroys the fire protection plan originally set out by the architect. |
Date | |
Source | Own work |
Author | Achim Hering |
Licensing
editPublic domainPublic domainfalsefalse |
![]() |
I, the copyright holder of this work, release this work into the public domain. This applies worldwide. In some countries this may not be legally possible; if so: I grant anyone the right to use this work for any purpose, without any conditions, unless such conditions are required by law. |
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 22:56, 27 May 2007 | ![]() | 2,336 × 3,448 (621 KB) | Achim Hering (talk | contribs) | {{Information |Description=This is typical '''passive fire protection''' problem. This wall is supposed to have a fire-resistance rating. It does not, because the firestop is inoperable. The plumber followed his instructions, to the letter, by providi |
You cannot overwrite this file.
File usage on Commons
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
_error | 0 |
---|