File:Investigating-the-Flow-Dynamics-in-the-Obstructed-and-Stented-Ureter-by-Means-of-a-Biomimetic-pone.0087433.s003.ogv
Size of this JPG preview of this OGG file: 800 × 450 pixels. Other resolutions: 320 × 180 pixels | 640 × 360 pixels | 1,280 × 720 pixels.
Original file (Ogg multiplexed audio/video file, Theora/Vorbis, length 34 s, 1,280 × 720 pixels, 422 kbps overall, file size: 1.69 MB)
File information
Structured data
Captions
Summary
editDescriptionInvestigating-the-Flow-Dynamics-in-the-Obstructed-and-Stented-Ureter-by-Means-of-a-Biomimetic-pone.0087433.s003.ogv |
English: Flow visualisation at a distance of 15 cm after the obstruction. Flow visualisation shows the fluid entering the stent side hole at a distance of 15 cm after the obstruction. |
||
Date | |||
Source | Video S3 from Clavica F, Zhao X, ElMahdy M, Drake M, Zhang X, Carugo D (2014). "Investigating the Flow Dynamics in the Obstructed and Stented Ureter by Means of a Biomimetic Artificial Model". PLOS ONE. DOI:10.1371/journal.pone.0087433. PMC: 3911952. | ||
Author | Clavica F, Zhao X, ElMahdy M, Drake M, Zhang X, Carugo D | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 22:04, 5 February 2014 | 34 s, 1,280 × 720 (1.69 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
The following page uses this file:
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Clavica F, Zhao X, ElMahdy M, Drake M, Zhang X, Carugo D |
---|---|
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Flow visualisation at a distance of 15 cm after the obstruction. Flow visualisation shows the fluid entering the stent side hole at a distance of 15 cm after the obstruction. |
Software used | |
Date and time of digitizing | 2014 |
Language | English |