File:Rotational-manipulation-of-single-cells-and-organisms-using-acoustic-waves-ncomms11085-s12.ogv
Size of this JPG preview of this OGG file: 799 × 311 pixels. Other resolutions: 320 × 125 pixels | 876 × 341 pixels.
Original file (Ogg Theora video file, length 8.7 s, 876 × 341 pixels, 5.6 Mbps, file size: 5.81 MB)
File information
Structured data
Captions
Summary edit
DescriptionRotational-manipulation-of-single-cells-and-organisms-using-acoustic-waves-ncomms11085-s12.ogv |
English: Supplementary Movie 11 Stepwise rotation of an L4 stage C. elegans. Multiple bubbles excited by varying duration of pulses at ~73.9 kHz and 20 VPP (peak-to-peak) are used to rotate an L4 stage C. elegans in a controlled manner. Relatively lower excitation frequencies provide a slower rotational speed for more accurate positional adjustments. Pulse duration varies from 5 milliseconds to 70 milliseconds which directly correlates to changes from smaller to larger angular steps. |
||
Date | |||
Source | Video file from Ahmed D, Ozcelik A, Bojanala N, Nama N, Upadhyay A, Chen Y, Hanna-Rose W, Huang T (2016). "Rotational manipulation of single cells and organisms using acoustic waves". Nature Communications. DOI:10.1038/ncomms11085. PMID 27004764. PMC: 4814581. | ||
Author | Ahmed D, Ozcelik A, Bojanala N, Nama N, Upadhyay A, Chen Y, Hanna-Rose W, Huang T | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 15:05, 28 October 2016 | 8.7 s, 876 × 341 (5.81 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Supplementary Movie 11 |
---|---|
Author | Ahmed D, Ozcelik A, Bojanala N, Nama N, Upadhyay A, Chen Y, Hanna-Rose W, Huang T |
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Stepwise rotation of an L4 stage C. elegans. Multiple bubbles excited by varying duration of pulses at ~73.9 kHz and 20 VPP (peak-to-peak) are used to rotate an L4 stage C. elegans in a controlled manner. Relatively lower excitation frequencies provide a slower rotational speed for more accurate positional adjustments. Pulse duration varies from 5 milliseconds to 70 milliseconds which directly correlates to changes from smaller to larger angular steps. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2016-03-23 |