File:Spiral-Wave-Dynamics-in-a-Mathematical-Model-of-Human-Ventricular-Tissue-with-Myocytes-and-pone.0072950.s010.ogv
Size of this JPG preview of this OGG file: 798 × 600 pixels. Other resolutions: 319 × 240 pixels | 639 × 480 pixels | 1,022 × 768 pixels | 1,200 × 902 pixels.
Original file (Ogg Theora video file, length 13 s, 1,200 × 902 pixels, 2.09 Mbps, file size: 3.12 MB)
File information
Structured data
Captions
Summary
editDescriptionSpiral-Wave-Dynamics-in-a-Mathematical-Model-of-Human-Ventricular-Tissue-with-Myocytes-and-pone.0072950.s010.ogv |
English: Spiral-wave dynamics in our 2D myocyte-fibroblast model in the presence of a square, MF-composite inhomogeneity, of side mm and with its lower-left-hand corner placed at ( mm, mm) for the case of doubled-sided coupling with and nS. (a) control case, i.e., with only myocytes; (b) ; (c) ; (d) . Here the myocyte transmembrane potential time evolution is shown for ; we use 10 frames per second (fps); in real time each frame is separated from the succeeding frame by 8 ms. |
||
Date | |||
Source | Video S9 from Nayak A, Shajahan T, Panfilov A, Pandit R (2013). "Spiral-Wave Dynamics in a Mathematical Model of Human Ventricular Tissue with Myocytes and Fibroblasts". PLOS ONE. DOI:10.1371/journal.pone.0072950. PMID 24023798. PMC: 3762734. | ||
Author | Nayak A, Shajahan T, Panfilov A, Pandit R | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 02:23, 14 September 2013 | 13 s, 1,200 × 902 (3.12 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Nayak A, Shajahan T, Panfilov A, Pandit R |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | Spiral-wave dynamics in our 2D myocyte-fibroblast model in the presence of a square, MF-composite inhomogeneity, of side mm and with its lower-left-hand corner placed at ( mm, mm) for the case of doubled-sided coupling with and nS. (a) control case, i.e., with only myocytes; (b) ; (c) ; (d) . Here the myocyte transmembrane potential time evolution is shown for ; we use 10 frames per second (fps); in real time each frame is separated from the succeeding frame by 8 ms. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2013 |